Water pressure protection——There will be error code when water pressure is less than 0.3 bar in case the product dry burning and also the water will be discharged from safety valve automatically when water pressure is higher than 3 bar.
Burning system protection——The product will display ignition malfunction when ignition failure occurs 3 times continuously
The product will display flame malfunction when ignition failure after the flame is extinguished during the product working
The product will display fake flame malfunction when the flame is deducted during the product standby status
Gas and electricity protection-It need manual recovery when the gas and electiricity is cut during the product working.